  "$schema": "og-gate-1.0",
  "module": "assembly",
  "variant": "baseline",
  "dim": "D14",
  "value": -63.0,
  "unit": "dB_worst_case_margin",
  "threshold_pass": 6.0,
  "threshold_obj": 16.5,
  "rag": "RED",
  "cas_score": 0.0,
  "cas_factors": {
    "verification": 3.0,
    "validation": 0.0,
    "input_pedigree": 2.0,
    "results_uncertainty": 2.0,
    "results_robustness": 1.0,
    "use_history": 2.0,
    "ms_management": 2.0,
    "people_qual": 2.0
  },
  "cas_rollup_policy": "OG-conservative-min (stricter than NASA-7009B App.B.4)",
  "validated_vs_reality": "PENDING",
  "risk_trace": [
    "R6",
    "R7"
  ],
  "evidence": "openEMS_genuine_solve=TRUE binary=/usr/bin/openEMS peak_probe_v=0.0000e+00 n_samples=385 analytical_pairs_checked=7 analytical_fail_count=4 analytical_worst_margin=-63.0dB emi_margins_json=/out/emi_margins_assembly_baseline.json",
  "tool": "gate_pyems_emi_q.py (openEMS=/usr/bin/openEMS, genuine FDTD solve; analytical emitter-victim matrix)",
  "standard": "MIL-STD-461G RE102/CE102/CS114/RS103; MIL-STD-464D system E3; analytical coupling model per Ott 'Electromagnetic Compatibility Engineering' (2009)",
  "ts": "2026-07-02T11:57:02.211955+00:00"
}